These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Cross-validation and evaluation of the performance of methods for the elemental analysis of forensic glass by μ-XRF, ICP-MS, and LA-ICP-MS.
    Author: Trejos T, Koons R, Becker S, Berman T, Buscaglia J, Duecking M, Eckert-Lumsdon T, Ernst T, Hanlon C, Heydon A, Mooney K, Nelson R, Olsson K, Palenik C, Pollock EC, Rudell D, Ryland S, Tarifa A, Valadez M, Weis P, Almirall J.
    Journal: Anal Bioanal Chem; 2013 Jun; 405(16):5393-409. PubMed ID: 23673570.
    Abstract:
    Elemental analysis of glass was conducted by 16 forensic science laboratories, providing a direct comparison between three analytical methods [micro-x-ray fluorescence spectroscopy (μ-XRF), solution analysis using inductively coupled plasma mass spectrometry (ICP-MS), and laser ablation inductively coupled plasma mass spectrometry]. Interlaboratory studies using glass standard reference materials and other glass samples were designed to (a) evaluate the analytical performance between different laboratories using the same method, (b) evaluate the analytical performance of the different methods, (c) evaluate the capabilities of the methods to correctly associate glass that originated from the same source and to correctly discriminate glass samples that do not share the same source, and (d) standardize the methods of analysis and interpretation of results. Reference materials NIST 612, NIST 1831, FGS 1, and FGS 2 were employed to cross-validate these sensitive techniques and to optimize and standardize the analytical protocols. The resulting figures of merit for the ICP-MS methods include repeatability better than 5% RSD, reproducibility between laboratories better than 10% RSD, bias better than 10%, and limits of detection between 0.03 and 9 μg g(-1) for the majority of the elements monitored. The figures of merit for the μ-XRF methods include repeatability better than 11% RSD, reproducibility between laboratories after normalization of the data better than 16% RSD, and limits of detection between 5.8 and 7,400 μg g(-1). The results from this study also compare the analytical performance of different forensic science laboratories conducting elemental analysis of glass evidence fragments using the three analytical methods.
    [Abstract] [Full Text] [Related] [New Search]