These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: 3-year clinical effectiveness of one-step adhesives in non-carious cervical lesions. Author: Moretto SG, Russo EM, Carvalho RC, De Munck J, Van Landuyt K, Peumans M, Van Meerbeek B, Cardoso MV. Journal: J Dent; 2013 Aug; 41(8):675-82. PubMed ID: 23747824. Abstract: OBJECTIVES: Despite representing an important component of current dental adhesives, HEMA has been said to negatively influence the long-term stability of adhesion to dentine and enamel. The aim of this randomised clinical trial was to evaluate the 3-year clinical performance of two one-step self-etch adhesives. METHODS: Thirty patients had 175 non-carious cervical lesions restored with composite (Gradia Direct Anterior, GC) using either the HEMA-rich adhesive Clearfil Tri-S Bond (C3S; Kuraray) or the HEMA-free adhesive G-Bond (GB; GC). The restorations were evaluated by two examiners at baseline, 6, 12, 24 and 36 months regarding retention, caries recurrence, marginal integrity and discoloration and post-operative sensitivity. The data were statistically analysed with GEE and McNemar tests (p<0.05). RESULTS: The recall rate at 6 and 12 months was 100% and decreased to 96.7% at 24 and 36 months. At 3 years, the retention rate was 93.8% for C3S and 98.8% for GB (p=0.14). A pairwise comparison showed no significant differences between the two adhesives for all the parameters evaluated, irrespective of the recall (p>0.05). After 3 years, both adhesives presented an increase in the percentage of clinically acceptable marginal discoloration (C3S: 32.9% and GB: 26.8%) normally associated to clinically acceptable marginal defects (C3S: 35.8% and GB: 26.5%). Only 1 dentine margin of a GB restoration presented a severe marginal defect (1.2%) and 1 C3S restoration presented caries recurrence. The overall 3-year clinical success rate was 92.6% for C3S and 97.6% for GB (p=0.16). CONCLUSION: Both one-step self-etch adhesives presented an equally favourable clinical effectiveness at 3 years. CLINICAL SIGNIFICANCE: HEMA is a monomer frequently present in dental adhesives in order to increase their wettability and hydrophilicity. However, this monomer negatively influences hydrolytic stability and durability of the adhesive interface complex. In this 3-year clinical trial no significant difference in bonding effectiveness was noticed between a HEMA-rich and HEMA-free one-step adhesive.[Abstract] [Full Text] [Related] [New Search]