These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Pharmacokinetics study of recombinant hirudin in the plasma of rats using chromogenic substrate, ELISA, and radioisotope assays. Author: Jiang SY, Jiao J, Zhang TT, Xu YP. Journal: PLoS One; 2013; 8(6):e64336. PubMed ID: 23785400. Abstract: AIM: To compare the analytical methods used to study the pharmacokinetics of recombinant hirudin in the plasma of rats that had been injected with (125)I-recombinant hirudin. METHODS: 2.0 mg/kg (125)I-recombinant hirudin were injected intravenously into rats. The recombinant hirudins in the plasma was analyzed by chromogenic substrate assay, enzyme-linked immunosorbent assay (ELISA), total radioisotope assay (RA) and trichloroacetic acid pre-treated total radioisotope assay (TCA-RA). RESULTS: The chromogenic substrate assay standard curve was linear over the concentration range from 3.12 to 40.00 ng/ml for the recombinant hirudin in plasma. The relative standard deviations (RSD) for the intra- and inter-day variation were 5.0 to 6.3% and 11.9 to 12.6%, respectively. The recoveries of recombinant hirudin was 89.8% to 100.7%. The limit of quantification (LOQ) was 3.12 ng/ml. The concentration-time curve of the recombinant hirudin in the plasma could be explained as a two-compartment model. Pharmacokinetic parameters, including the half-life of distribution phase (t1/2 α), the half-life of elimination phase (t1/2 β), volume of apparent distribution (Vd), and area under the concentration-time curve from zero to infinite time (AUC0-t) were 7.59 min, 46.99 min, 0.17 L/kg, and 204.5 mg/L/min, respectively, as determined by chromogenic substrate assay; 6.41 min, 47.28 min, 1.24 L/kg, and 575.18 mg/L/min, respectively, as determined by ELISA; 3.69 min, 701.90 min, 0.04 L/kg, and 4189 mg/L/min, respectively as determined by RA; and 4.57 min, 724.9 min, 0.09 L/kg, and 2329 mg/L/min, respectively, as determined by TCA-RA. CONCLUSIONS: The chromogenic substrate assay on the concentration dynamics of the recombinant hirudin in the plasma is a specific, sensitive, and accurate analytical method for pharmacokinetic studies. Moreover, the pharmacokinetic parameters determined by the chromogenic substrate assay and ELISA are congruent except for AUC.[Abstract] [Full Text] [Related] [New Search]