These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Determination of chromium in capsule by inductively coupled plasma-mass spectrometry].
    Author: Chen X, Zhang M, Fu H, Xu C, Lin S.
    Journal: Wei Sheng Yan Jiu; 2013 May; 42(3):510-3. PubMed ID: 23805537.
    Abstract:
    OBJECTIVE: To establish the method which determined the content of chromium(Cr) in capsule by inductively coupled plasma-mass spectrometry. METHODS: Pre-digestion-microwave digestion procedures were applied to extract Cr from the capsules. The potentially interfering 40Ar12C+ and 37Cl16O+ at the chromium masses m/z 52 and 53 were reduced in intensity by approximately 2 orders of magnitude by using 0. 6 ml/min NH3 as reactive cell gas in the dynamic reaction cell (DRC) while a Rpq value of 0.55 was used. RESULTS: The correlation coefficient (r) of standard curve was 0.9996, and the detection limit of the method was 0.03 mg/kg, and the average recoveries for all determinations ranged from 86.5% to 107.8% with the related standard deviation below 5%. CONCLUSION: The method, which is of good precision and accuracy, is applicable to rapid and accurate determination of chromium content in capsule.