These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Additive value of magnetic resonance coronary angiography in a comprehensive cardiac magnetic resonance stress-rest protocol for detection of functionally significant coronary artery disease: a pilot study.
    Author: Bettencourt N, Ferreira N, Chiribiri A, Schuster A, Sampaio F, Santos L, Melica B, Rodrigues A, Braga P, Teixeira M, Leite-Moreira A, Silva-Cardoso J, Portugal P, Gama V, Nagel E.
    Journal: Circ Cardiovasc Imaging; 2013 Sep; 6(5):730-8. PubMed ID: 23833284.
    Abstract:
    BACKGROUND: Cardiovascular magnetic resonance (CMR) myocardial perfusion imaging (MPI) is a state-of-the-art noninvasive modality for detection of myocardial ischemia and coronary artery disease. Magnetic resonance coronary angiography (MRCA) allows visualization of the coronary tree, but its incremental value as part of a CMR protocol including MPI and late gadolinium enhancement (LGE) is not well established. We aimed to evaluate the additive diagnostic value of a 3-dimensional whole-heart MRCA integration into a 1.5T CMR-MPI/LGE protocol for the detection of functionally significant coronary artery disease. METHODS AND RESULTS: Forty-three symptomatic patients (61 ± 8.3 years; 65% men) with suspected coronary artery disease and intermediate/high-pretest probability underwent CMR (including CMR-MPI, MRCA, and LGE) and x-ray invasive coronary angiography (XA) with fractional flow reserve evaluation. Diagnostic performances of MRCA, CMR-MPI/LGE, and MRCA+CMR-MPI/LGE integration were determined having XA+fractional flow reserve as standard for coronary artery disease (≥90% stenosis/occlusion or fractional flow reserve ≤ 0.80 in vessels>2 mm). MRCA inclusion into the CMR protocol was associated with a mean increase of 7.9 ± 4.69 (0-17.7) minutes in total examination duration (14%). On patient-based analysis, MRCA had 96% sensitivity, 68% specificity, positive predictive value of 79%, and negative predictive value of 93%. CMR-MPI/LGE had 79% sensitivity, 95% specificity, positive predictive value of 95%, and negative predictive value of 78%. Integration of MRCA with CMR-MPI/LGE further improved CMR performance to 96% sensitivity, 89% specificity, positive predictive value of 92%, and negative predictive value of 94%, with a global accuracy of 93%. CONCLUSIONS: In this intermediate/high-pretest population, integration of noncontrast-enhanced whole-heart MRCA nonsignificantly improved per-patient diagnostic accuracy of a comprehensive 1.5-T stress-rest CMR-MPI/LGE protocol at a cost of longer scanning times.
    [Abstract] [Full Text] [Related] [New Search]