  • Title: Evaluation of blind nasotracheal suctioning and non-bronchoscopic mini-bronchoalveolar lavage in critically ill patients with infectious pneumonia: a preliminary study.
    Author: Meyer P, Rousseau H, Maillet JM, Thierry S, Sy O, Vicaut E, Thiolliere F, Choukroun G, Chergui K, Chevrel G, Maury E.
    Journal: Respir Care; 2014 Mar; 59(3):345-52. PubMed ID: 23882105.
    Abstract:
    BACKGROUND: We evaluated the diagnostic performance and safety of combined blind nasotracheal suctioning and non-bronchoscopic mini-bronchoalveolar lavage (mini-BAL) to obtain respiratory secretion specimens from spontaneously breathing, non-intubated patients with infectious pneumonia in intensive care. METHODS: Patients suspected of having infectious pneumonia were included prospectively. Three samples were obtained: expectorated sputum, nasotracheal suctioning, and mini-BAL via a double telescopic catheter (Combicath). Under local anesthesia, nasotracheal suctioning was done according to standard recommendations. Then mini-BAL was performed; the bronchial catheter serves as a guide for the mini-BAL catheter, and tracheal position is verified via colorimetric capnography. RESULTS: We included 36 subjects (29 men, median age 69 y, median Simplified Acute Physiology Score II 32), of which 32 (89%) underwent nasotracheal suctioning and mini-BAL, and from 13 (36%) we collected expectorated sputum. Based on colorimetric capnography confirmation of the tracheal position, 75% (24/32) of the successful combined procedures were achieved on the first attempt. The median duration of the combined procedure was 7 min. Bacterial pneumonia was diagnosed in 24/36 (67%) subjects, among whom 21 (88%) had undergone successful nasotracheal suctioning and mini-BAL, respectively, for 8/21 (38% [95% CI 0.17-0.58%] and 14/21 (67% [95% CI 0.46-0.86%]). Mini-BAL diagnosed a significantly higher percentage of bacterial pneumonias than did nasotracheal suctioning. Expectorated sputum yielded no diagnoses. CONCLUSIONS: Blind nasotracheal suctioning confirmed via colorimetric capnography allows microbiological diagnosis, and can be enhanced by non-bronchoscopic mini-BAL. Colorimetric capnography helps confirm bronchial tube position. Non-bronchoscopic mini-BAL is a novel and feasible way to collect bronchial secretions without fibroscopy. (ClinicalTrials.gov NCT00763620.).
    [Abstract] [Full Text] [Related] [New Search]