These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Differential impact of cilostazol on restenosis according to implanted stent type (from a pooled analysis of three DECLARE randomized trials). Author: Lee SW, Ahn JM, Han S, Park GM, Cho YR, Lee WS, Jang JY, Kwon CH, Lee JY, Kim WJ, Kang SJ, Kim YH, Lee CW, Kim JJ, Park SW, Park SJ. Journal: Am J Cardiol; 2013 Nov 01; 112(9):1328-34. PubMed ID: 23890573. Abstract: Even in the drug-eluting stent era, restenosis has remained an unresolved issue, particularly in the treatment of complex coronary lesions. In this study, patient-level data from 3 randomized trials (Drug-Eluting Stenting Followed by Cilostazol Treatment Reduces Late Restenosis in Patients With Diabetes Mellitus [DECLARE-DIABETES] and Drug-Eluting Stenting Followed by Cilostazol Treatment Reduces Late Restenosis in Patients With Long Native Coronary Lesions [DECLARE-LONG] I and II) were pooled to estimate the differential antirestenotic efficacy of add-on cilostazol according to the implanted drug-eluting stent in patients at high risk for restenosis. A total of 1,399 patients underwent sirolimus-eluting stent (SES; n = 450), paclitaxel-eluting stent (n = 450), and zotarolimus-eluting stent (n = 499) implantation and received triple-antiplatelet therapy (TAT; aspirin, clopidogrel, and cilostazol, n = 700) and dual-antiplatelet therapy (aspirin and clopidogrel, n = 699). Randomization of antiplatelet regimen was stratified by stent type. In-stent late loss after TAT was significantly lower than that after dual-antiplatelet therapy, regardless of implanted stent type. However, the incidence of in-segment restenosis after TAT was significantly lower with SES (0.5% vs 6.7%, p = 0.014) and zotarolimus-eluting stent (12.2% vs 20.0%, p = 0.028) implantation but not paclitaxel-eluting stent implantation (14.4% vs 20.0%, p = 0.244). A significant interaction was present between stent type and antiplatelet regimen for the risk for in-segment restenosis (p = 0.004). Post hoc analysis using bootstrap resampling methods showed that the relative risk reduction for in-segment restenosis after TAT was most prominent with SES implantation. In conclusion, add-on cilostazol effectively reduced restenosis in patients at high risk for restenosis, particularly in those receiving SES, suggesting the sustainable utility of add-on cilostazol therapy in newer generation drug-eluting stents with comparable efficacy with that of SES.[Abstract] [Full Text] [Related] [New Search]