These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Influences of cycle index and volume on sensitivity of DNA detection]. Author: Zhang L, Wang BJ, Ding M, Lin ZQ, Pang H, Xing JX, Xuan JF. Journal: Fa Yi Xue Za Zhi; 2013 Apr; 29(2):125-6. PubMed ID: 23930508. Abstract: OBJECTIVE: To explore the feasibility of improving the sensitivity of DNA detection by increasing the PCR cycle index and decreasing the volume of amplifying system. METHODS: The DNA of semen were collected from 10 healthy irrelevant volunteers, and were quantified to 50, 40, 30, 25, 20, 15, 10 pg/microL, separately. All samples were then amplified in 10, 5, 3 microL volume and at 28, 30, 32, 34, 36 cycles, respectively. 3130 genetic analyzer was used to detect 15 autosomal STR loci. RESULTS: Under the situation of 28 cycles and 3 microL volume, samples which achieved > 40 pg/microL could be correctly typed. Under the situation of 10, 5, 3 microL volume, samples which achieved > 20 pg/microL could be correctly typed at 34 cycles. When increasing the index to 36 cycles, they could not be correctly typed because of the non-specific band. CONCLUSION: DNA detecting sensitivity can be improved to a certain extent by increasing the cycle index and decreasing the volume of amplifying system.[Abstract] [Full Text] [Related] [New Search]