These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Storage phosphor versus screen-film radiography: effect of varying exposure parameters and unsharp mask filtering on the detectability of cortical bone defects.
    Author: Prokop M, Galanski M, Oestmann JW, von Falkenhausen U, Rosenthal H, Reimer P, Nischelsky J, Reichelt S.
    Journal: Radiology; 1990 Oct; 177(1):109-13. PubMed ID: 2399307.
    Abstract:
    Diagnostic performance with storage phosphor radiography is influenced by exposure parameters and digital filtering algorithms. The authors compared the detectability of cortical lesions in excised human femoral shafts on state-of-the-art screen-film radiographs and storage phosphor digital radiographs. For the digital system, the effect of varying exposure parameters (photon flux and tube voltage) and unsharp mask filtering (kernel size and enhancement factor) was tested. Analysis of receiver operating characteristics was performed for 10,560 observations made by eight radiologists. Under identical exposure conditions, storage phosphor imaging yielded no significant advantages over conventional screen-film radiography. Although large variations in exposure dose are possible with storage phosphors, the potential for dose reduction was limited even by means of an increase in tube voltage. The performance with unsharp masked images declined with decreasing kernel size and pronounced enhancement.
    [Abstract] [Full Text] [Related] [New Search]