These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Functional annulus remodelling using a prosthetic ring in tricuspid aortic valve repair: mid-term results.
    Author: Fattouch K, Castrovinci S, Murana G, Nasso G, Guccione F, Dioguardi P, Salardino M, Bianco G, Speziale G.
    Journal: Interact Cardiovasc Thorac Surg; 2014 Jan; 18(1):49-54; discussion 54-5. PubMed ID: 24065345.
    Abstract:
    OBJECTIVES: The functional aortic valve annulus (FAVA) is a complex unit with proximal (aorto-ventricular junction) and distal (sinotubular junction) components. The aim of our study was to evaluate the impact of the total FAVA remodelling, using a prosthetic ring, on mid-term clinical and echocardiographic results after aortic valve repair. METHODS: Since February 2003, 250 patients with tricuspid aortic valve insufficiency (AI) underwent aortic valve repair. FAVA dilatation was treated by prosthetic ring in 52 patients, by isolated subcommissural plasty in 62, by subcommissural plasty plus ascending aortic replacement in 57 and by David's reimplantation procedure in 79. Survival rate and freedom from recurrent AI greater than or equal to moderate were evaluated by Kaplan-Meier. RESULTS: Overall late survival was 90.4%. Late cardiac-related deaths occurred in 15 patients. At follow-up, 36 (16%) patients had recurrent AI greater than or equal to moderate because of cusp reprolapse and/or FAVA redilatation. Freedom from recurrent AI was significantly higher for patients who underwent David's procedure or FAVA remodelling by prosthetic ring than those who underwent isolated subcommissural plasty (P < 0.01) or subcommissural plasty plus ascending aortic replacement (P = 0.02). There was no statistical difference between David's procedure and prosthetic ring annuloplasty (P = 0.26). CONCLUSION: FAVA remodelling using a prosthetic ring is a safe procedure in aortic valve repair surgery thanks to long-term annulus stabilization and it is a pliable alternative to David's procedure in selected patients. This technique may be used in all patients with slight root dilatation to avoid aggressive root reimplantation. We also recommended total FAVA annuloplasty in all patients who underwent aortic valve repair to improve long-term repair results.
    [Abstract] [Full Text] [Related] [New Search]