These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: The effect of type of restoration on the stress field developed in terminal abutments with severely reduced periodontal support and coronal structure. Author: Stasinopoulou I, Manda M, Galanis C, Koidis P. Journal: J Prosthet Dent; 2013 Oct; 110(4):303-12. PubMed ID: 24079566. Abstract: STATEMENT OF PROBLEM: Periodontally compromised teeth (PCT) that serve as terminal abutments (TAs) are often challenging depending on the post-and-core treatment, the type of partial fixed dental prosthesis (PFDP), and the periodontal support. PURPOSE: The purpose of this study was to investigate the biomechanical impact of 3 types of PFDP supported by cast post-and-cores on PCT serving as terminal abutments. MATERIAL AND METHODS: A 3-dimensional (3D) model of a human mandible was fabricated by using computed tomography (CT) images and parameterized in a computer-aided design (CAD) environment as follows: Right premolar preparation geometries were designed. The second premolar was assembled with 7-mm or 10-mm cast post-and-core models. Both premolar-models were designed to support single, splinted, or 1-unit cantilever splinted crowns. In each situation, their periodontium geometries were designed to be reduced by 10%, 50%, and 70%. All models were imported into a 3D finite element analysis (FEA) environment and loaded; von Mises stress values and distribution patterns were evaluated. RESULTS: Insertion of the post primarily affected the apical areas of both the root and post; the type of PFDP and periodontal support mainly affected stress distribution. In patients with a normal periodontium, splinting the teeth did not contribute to their stress relief. By extending the post length, a stressful area close to the apex of the post was developed. Splinting mitigated the stress field of the coronal part of the 50% PCT (up to 98.9%); the 30% PCT experienced a substantial decrease (up to 215.9%) in stress in the radical part as well. The increase in the length of the post produced negligible stress-related differences in the apical part of the 50% PCT (0.2% to 2.6%). The use of the 7-mm post effectively relieved the radical part of the splinted 30% PCT. The magnitude of the stress on the radical part of post-restored PCT was considerably increased in the presence of a cantilever. CONCLUSIONS: Splinted crowns supported by a 7-mm cast post-and-core are a favorable biomechanical approach for the restoration of PCT with severe loss of coronal structure. The use of a cantilever greatly aggravates the biomechanical response, especially of post-restored PCT.[Abstract] [Full Text] [Related] [New Search]