These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Correlation of fetal heart rate-uterine contraction patterns with fetal scalp blood pH.
    Author: Tejani N, Mann LI, Bhakthavathsalan A, Weiss RR.
    Journal: Obstet Gynecol; 1975 Oct; 46(4):392-6. PubMed ID: 241036.
    Abstract:
    The significance of fetal heart rate-uterine contraction (FHR-UC) monitoring as a means of predicting the condition of the fetus during labor was studied by correlating 460 fetal pH determinations obtained from 216 patients with the analysis of the 20-minute FHR-UC record preceding the fetal scalp blood sample. Both qualitative and quantitative analyses of the FHR-UC record were performed. The results indicate a less than 10% chance of fetal pH less than or equal to 7.250 with an normal baseline FHR and no periodic changes or with periodic accelerations, early decelerations, and uncomplicated baseline bradycardia or tachycardia. Variable or delayed decelerations with a total surface area (TSA) of 1-100 for the 20-min period were associated with a fetal pH less than or equal to 7.250 in 23 and 34% of cases, respectively. Variable or delayed decelerations with a TSA greater than 100 had a 35 or 47% chance of fetal pH less than or equall to 7.250. It is concluded that FHR-UC monitoring can be used to screen the innocuous from the ominous periodic change but that fetal scalp blood pH must be obtained to identify accurately the true from the false-positive ominous pattern.
    [Abstract] [Full Text] [Related] [New Search]