These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Cationic eluate pretreatment for automated synthesis of [⁶⁸Ga]CPCR4.2.
    Author: Martin R, Jüttler S, Müller M, Wester HJ.
    Journal: Nucl Med Biol; 2014 Jan; 41(1):84-9. PubMed ID: 24120219.
    Abstract:
    Fostered by the clinical success of sst-ligands, the development and evaluation of (68)Ga-labeled peptides have become a very active field in radiopharmaceutical chemistry. Consequently, various new peptide tracers have been developed, e.g. [(68)Ga]CPCR4.2 for in vivo imaging of solid and haematological tumors or [(68)Ga]TRAP(RGD)₃ for imaging of α(v)β₃ integrin expression. As a consequence of different matrices (TiO₂, SnO₂, polymers) exploited in commercial (68)Ge/(68)Ga-generators, HCl of different concentrations (0.05...1.0 M) is used to obtain (68)Ga as starting material for automated syntheses. We have developed a purification method which reduces the eluate volume and adjusts the HCl concentration. The method may potentially allow standardization of the eluate composition of different commercial generators prior to labeling. Recently, a cationic purification process has been reported which allows the pre-fixation of (68)Ga on a Varian SCX cation exchange cartridge and subsequent elution of (68)Ga with acidified NaCl solutions. As part of the development of ready-to-use cassettes for the automated production of (68)Ga-CPCR4.2 using a SCINTOMICS GRP module and an iThemba Labs generator that is eluted with 0.6...1.0 M HCl, we tested and compared the (68)Ga-trapping efficiency of various commercial available cation exchange cartridges, the efficiency of subsequent (68)Ga-elution from these cartridges by means of various protocols and the influence of these variations on the labeling efficiency of [(68)Ga]CPCR4.2, [(68)Ga]TRAP(RGD)₃ and [(68)Ga]DOTATATE/[(68)Ga]DOTANOC. Finally, we transferred the optimized method to the automated, cassette based synthesis of [(68)Ga]CPCR4.2 and the aforementioned peptides. From seven tested cation exchange cartridges, Chromafix PS-H(+) gave the best extraction results (>95%). Moreover, we observed that acidified solutions of 5 M NaCl or 2.5 M CaCl₂ can be used for efficient cartridge elution. Using a disposable cGMP-compliant cassette system, we obtained [(68)Ga]CPCR4.2 in 80% decay-corrected yield and >99% purity. These data were confirmed by the production of [(68)Ga]DOTATATE, [(68)Ga]DOTANOC and [(68)Ga]TRAP(RGD)3 on the otherwise identical cassette system.
    [Abstract] [Full Text] [Related] [New Search]