These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Prognostic utility of 90Y radioembolization dosimetry based on fusion 99mTc-macroaggregated albumin-99mTc-sulfur colloid SPECT. Author: Lam MG, Goris ML, Iagaru AH, Mittra ES, Louie JD, Sze DY. Journal: J Nucl Med; 2013 Dec; 54(12):2055-61. PubMed ID: 24144563. Abstract: UNLABELLED: Planning hepatic (90)Y radioembolization activity requires balancing toxicity with efficacy. We developed a dual-tracer SPECT fusion imaging protocol that merges data on radioactivity distribution with physiologic liver mapping. METHODS: Twenty-five patients with colorectal carcinoma and bilobar liver metastases received whole-liver radioembolization with resin microspheres prescribed as per convention (mean administered activity, 1.69 GBq). As part of standard treatment planning, all patients underwent SPECT imaging after intraarterial injection of 37 MBq of (99m)Tc-macroaggregated albumin ((99m)Tc-MAA) to simulate subsequent (90)Y distribution. Immediately afterward, patients received 185 MBq of labeled sulfur colloid ((99m)Tc-SC) intravenously as a biomarker for normal hepatic reticuloendothelial function and SPECT was repeated. The SPECT images were coregistered and fused. A region-based method was used to predict the (90)Y radiation absorbed dose to functional liver tissue (DFL) by calculation of (99m)Tc-MAA activity in regions with (99m)Tc-SC uptake. Similarly, the absorbed dose to tumor (DT) was predicted by calculation of (99m)Tc-MAA activity in voxels without (99m)Tc-SC uptake. Laboratory data and radiographic response were measured for 3 mo, and the survival of patients was recorded. SPECT-based DT and DFL were correlated with parameters of toxicity and efficacy. RESULTS: Toxicity, as measured by increase in serum liver enzymes, correlated significantly with SPECT-based calculation of DFL at all time points (P < 0.05) (mean DFL, 27.9 Gy). Broad biochemical toxicity (>50% increase in all liver enzymes) occurred at a DFL of 24.5 Gy and above. In addition, in uni- and multivariate analysis, SPECT-based calculation of DT (mean DT, 44.2 Gy) correlated with radiographic response (P < 0.001), decrease in serum carcinoembryonic antigen (P < 0.05), and overall survival (P < 0.01). The cutoff value of DT for prediction of 1-y survival was 55 Gy (area under the receiver-operating-characteristic curve = 0.86; P < 0.01). Patients who received a DT of more than 55 Gy had a median survival of 32.8 mo, compared with 7.2 mo in patients who received less (P < 0.05). CONCLUSION: Dual-tracer (99m)Tc-MAA-(99m)Tc-SC fusion SPECT offers a physiology-based imaging tool with significant prognostic power that may lead to improved personalized activity planning.[Abstract] [Full Text] [Related] [New Search]