  • Title: Speciation, adsorption and determination of chromium(III) and chromium(VI) on a mesoporous surface imprinted polymer adsorbent by combining inductively coupled plasma atomic emission spectrometry and UV spectrophotometry.
    Author: Liu Y, Meng X, Han J, Liu Z, Meng M, Wang Y, Chen R, Tian S.
    Journal: J Sep Sci; 2013 Dec; 36(24):3949-57. PubMed ID: 24151162.
    Abstract:
    In the present study, a Cr(III)-imprinted polymer (Cr(III)-IIP) was prepared by an easy one-step sol-gel reaction with a surface imprinting technique on the support of silica mesoporous material. A new SPE method for the speciation, separation, preconcentration, and determination of Cr(III) and Cr(VI) by inductively coupled plasma atomic emission spectrometry and UV on the mesoporous-imprinted polymer adsorbent was developed. The structure of the imprinted polymer was characterized by Fourier transform infrared spectroscopy, X-ray powder diffraction, transmission electron microscopy, and nitrogen adsorption-desorption isotherms. The adsorption kinetics, thermodynamics behavior, and recognition ability toward Cr(III) on Cr(III)-IIP and nonimprinted polymer were compared. The results showed that Cr(III)-IIP had higher selectivity and nearly a two times larger Langmuir adsorption capacity (38.50 mg/g) than that of NIP. The proposed method has been successfully applied in the determination and speciation of chromium in natural water samples with satisfactory results.