Search MEDLINE/PubMed
Title: Mercury-cadmium-telluride waveguides--a novel strategy for on-chip mid-infrared sensors. Author: Wang X, Antoszewski J, Putrino G, Lei W, Faraone L, Mizaikoff B. Journal: Anal Chem; 2013 Nov 19; 85(22):10648-52. PubMed ID: 24160678. Abstract: We report the first planar waveguides made from mercury-cadmium-telluride (MCT)-a material to date exclusively used for mid-infrared (MIR) detector elements-serving as on-chip MIR evanescent field transducers in combination with tunable quantum cascade lasers (tQCLs) emitting in the spectral regime of 5.78-6.35 μm. This novel MIR sensing approach utilizes structured MCT chips fabricated via molecular beam epitaxy (MBE) as waveguide enabling sensing via evanescent field absorption spectroscopy, as demonstrated by the detection of 1 nL of acetone. Complementary finite difference time domain (FDTD) simulations fit well with the experimentally obtained data and predict an improvement of the limit of detection by at least 2 orders of magnitude upon implementation of thinner MCT waveguides. With the first demonstration of chemical sensing using on-chip MCT waveguides, monolithically fabricated IR sensing systems directly interfacing the waveguide with the MCT detector element may be envisaged.[Abstract] [Full Text] [Related] [New Search]