These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Toward consistent terminology: assessment and reporting of amniotic fluid volume.
    Author: Moise KJ.
    Journal: Semin Perinatol; 2013 Oct; 37(5):370-4. PubMed ID: 24176162.
    Abstract:
    Amniotic fluid is typically measured by ultrasound using the amniotic fluid index (AFI) or the maximum vertical pocket (MVP). Although both parameters correlate poorly with the actual amniotic fluid volume measured with dye-dilution methods, cross-sectional studies have been used to establish gestational norms. The current acceptable definition of polyhydramnios in the late second and the third trimester in both singleton and multiple gestations is a MVP > 8 cm, while the definition of oligohydramnios is a MVP < 2 cm. The pocket to be measured should exclude the umbilical cord or fetal parts. Randomized clinical trials have indicated that defining oligohydramnios as a MVP < 2 cm will result in fewer obstetrical interventions and similar perinatal outcomes when compared to an AFI < 5 cm.
    [Abstract] [Full Text] [Related] [New Search]