These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Clinical outcomes with bioabsorbable polymer- versus durable polymer-based drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysis.
    Author: Palmerini T, Biondi-Zoccai G, Della Riva D, Mariani A, Sabaté M, Smits PC, Kaiser C, D'Ascenzo F, Frati G, Mancone M, Genereux P, Stone GW.
    Journal: J Am Coll Cardiol; 2014 Feb 04; 63(4):299-307. PubMed ID: 24211507.
    Abstract:
    OBJECTIVES: This study sought to investigate the relative safety and efficacy of bioabsorbable polymer (BP)-based biolimus-eluting stents (BES) versus durable-polymer (DP)-drug-eluting stents (DES) and bare-metal stents (BMS) by means of a network meta-analysis. BACKGROUND: Studies have suggested that BP-BES might reduce the risk of stent thrombosis (ST) and late adverse outcomes compared with first-generation DES. However, the relative safety and efficacy of BP-BES versus newer-generation DES coated with more biocompatible DP have not been investigated in depth. METHODS: Randomized controlled trials comparing BP-BES versus currently U.S.-approved DES or BMS were searched through MEDLINE, EMBASE, and Cochrane databases. Information on study design, inclusion and exclusion criteria, sample characteristics, and clinical outcomes was extracted. RESULTS: Data from 89 trials including 85,490 patients were analyzed. At 1-year follow-up, BP-BES were associated with lower rates of cardiac death/myocardial infarction (MI), MI, and target vessel revascularization (TVR) than BMS and lower rates of TVR than fast-release zotarolimus-eluting stents. The BP-BES had similar rates of cardiac death/MI, MI, and TVR compared with other second-generation DP-DES but higher rates of 1-year ST than cobalt-chromium everolimus-eluting stents (CoCr-EES). The BP-BES were associated with improved late outcomes compared with BMS and paclitaxel-eluting stents, considering the latest follow-up data available, with nonsignificantly different outcomes compared with other DP-DES although higher rates of definite ST compared with CoCr-EES. CONCLUSIONS: In this large-scale network meta-analysis, BP-BES were associated with superior clinical outcomes compared with BMS and first-generation DES and similar rates of cardiac death/MI, MI, and TVR compared with second-generation DP-DES but higher rates of definite ST than CoCr-EES.
    [Abstract] [Full Text] [Related] [New Search]