These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Aortic root replacement with a stented bioprosthetic valved conduit: mid-term results. Author: Gatti G, Dell'Angela L, Pinamonti B, Moncada A, Minati A, Benussi B, Sinagra G, Pappalardo A. Journal: J Heart Valve Dis; 2013 Jul; 22(4):500-8. PubMed ID: 24224412. Abstract: BACKGROUND AND AIM OF THE STUDY: For patients who require aortic root replacement but are unwilling or unable to receive anticoagulants, a composite conduit was assembled intraoperatively that contained a stented biological valve sutured inside a vascular tube graft, rather than at its extremity. This simple modification of the Bentall concept may provide several advantages. The results obtained with this conduit over an 11-year period were analyzed. METHODS: Between May 2001 and April 2012, 101 consecutive patients (mean age 68.3 +/- 9.2 years) underwent aortic root replacement with the bioprosthetic valved conduit. Aortic pathologies included degenerative disease in 61 patients (60.4%), atherosclerosis in 20 (19.8%), annuloaortic ectasia in 12 (11.9%), porcelain aorta in four (4.0%), and acute dissection in four (4.0%). The whole ascending aorta was replaced in 79 patients (78.2%); a hemiarch reconstruction and a total arch replacement were added in 18 (17.8%) and four (4.0%) patients, respectively. Hypothermic circulatory arrest was performed in 60 cases (59.4%). Forty patients (39.6%) underwent additional cardiac procedures. All perioperative data were collected prospectively. RESULTS: There were five (5.0%) hospital deaths. During a mean follow up of 3.8 +/- 2.4 years there were two non-valve-related cardiac deaths and five noncardiac deaths. The seven-year actuarial survival was 79.2% (95% CI 67.0-91.4%). Bioprosthetic structural dysfunction occurred in only one patient; reoperation was easily performed by replacing the valve within the vascular graft. In the remaining 88 patients (87.1%), echocardiographic assessment showed a low transaortic mean pressure gradient (7.2 +/- 4.7 mmHg) and left ventricular wall mass reduction (p = 0.0002). CONCLUSION: This valved conduit is a safe and durable option for replacing the aortic root, thus facilitating the technique of implantation and simplifying reoperation in the case of valve failure.[Abstract] [Full Text] [Related] [New Search]