These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Preliminary results of whole breast helical tomotherapy with simultaneous integrated boost in the adjuvant treatment of breast cancer]. Author: Liem X, Chira C, Fourquet A, Campana F, Peurien D, Fournier-Bidoz N, Kirova YM. Journal: Cancer Radiother; 2014 Jan; 18(1):15-22. PubMed ID: 24316350. Abstract: PURPOSE: To evaluate the dosimetry and acute toxicity of helical tomotherapy for locoregional irradiation of patients after breast-conserving surgery. PATIENTS AND METHODS: Twenty breast cancer patients with breast-conserving surgery treated by helical tomotherapy have been studied. The median age was 49 (min: 25, max: 69). The whole breast, tumour bed and lymph nodes were prescribed 52.2 Gy, 63.8 Gy and 50.4 Gy, all in 29 fractions. The dose per fraction was 2.2 Gy to the boost, 1.8 Gy to the breast and 1.74 Gy to the lymph node volumes. The reproducibility was analysed by recording the daily shifts in x, y and z directions and roll rotation. All toxicities were described using the Common Terminology Criteria for Adverse Effects v3.0. RESULTS: Twenty-two tumours were irradiated. Six-eight percent were located in the inner quadrant. In 90 % of patients supraclavicular and internal mammary nodes were treated. The coverage of planning target volumes (PTV) was as follows: PTV boost: V107 = 0.3 % ± 0.5 SD, V95 = 98.4 % ± 1.9 SD; PTV breast: -V107 = 7.8 % ± 17.3 SD, V95 = 96.8 % ± 2.2 SD; PTV LN: V107 = 2.5 % ± 4.2 SD, V95 = 92.7 % ± 13.2 SD. The mean V20 of the homolateral lung was 18.9 % ± 3.5 SD. For left side lesion, the mean V30 of the heart was 0.9 % ± 0.8 SD. The mean V5 was: V5 homolateral lung: 73.1 % ± 11.8 ET, controlateral lung: 38.9 % ± 21, heart (left side breast): 57.3 % ± 21, controlateral breast: 15.5 % ± 9.6. Median shifts were as follow: x-axis -0.04 mm (IC 95: -0.4 +0.38), y-axis -0.37 mm ± 5.51 (IC 95: -0.88 +0.14), z-axis 2.90 mm ± 5.42 (IC 95:+2.4+3.4) and roll rotation 0.22 ± 1.10 (IC 95: -0.1+0.32). The treatment tolerance was acceptable with 1 definitive interruption couple of fractions before the end and 3 temporal interruptions for skin toxicity. No grade 3 or 4 toxicity. Ninety-five percent of patients experienced skin toxicity: 45 % grade 2. There were 3 cases of oesophagitis. The median follow-up of presented series is 9.7 months and all of the patients are free of disease without any residual early or late toxicity. CONCLUSIONS: Helical tomotherapy can achieve full target coverage while protected to the heart and ipsilateral lung. This treatment was well tolerated and reproducible. However, the low doses to normal tissue volumes need to be reduced in future studies.[Abstract] [Full Text] [Related] [New Search]