These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: A novel approach for hybrid repair of type B aortic dissection associated with coarctation of the aorta. Author: Li Y, Fan Z, Huang L, Xue Y, Sun L. Journal: J Vasc Surg; 2014 May; 59(5):1422-5. PubMed ID: 24342070. Abstract: We report the case of an acute type B aortic dissection in association with an unknown isthmic coarctation in a 53-year-old man. An intimal tear was located just distal to the coarctation, and the intimal flap extended to the level of the renal arteries. Hybrid repair was performed successfully 4 months later, without deep hypothermic circulatory arrest. An extra-anatomic bypass connected the ascending aorta to the abdominal aorta. The coarctation was occluded using a ventricular septal defect occluder. The hybrid repair was safe and effective for the patient.[Abstract] [Full Text] [Related] [New Search]