These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Paclitaxel-eluting balloon vs. standard angioplasty to reduce recurrent restenosis in diabetic patients with in-stent restenosis of the superficial femoral and proximal popliteal arteries: the DEBATE-ISR study.
    Author: Liistro F, Angioli P, Porto I, Ricci L, Ducci K, Grotti S, Falsini G, Ventoruzzo G, Turini F, Bellandi G, Bolognese L.
    Journal: J Endovasc Ther; 2014 Feb; 21(1):1-8. PubMed ID: 24502477.
    Abstract:
    PURPOSE: To test the ability of a drug-eluting balloon (DEB) to reduce recurrent in-stent restenosis (ISR) in diabetic patients with femoropopliteal stents. METHODS: A prospective all-comers study [Drug-Eluting Balloon in Peripheral Intervention for In-Stent Restenosis (DEBATE-ISR); ClinicalTrials.gov identifier NCT01558531] of symptomatic diabetic patients with femoropopliteal ISR undergoing treatment with paclitaxel-eluting balloons was designed to compare their 12-month recurrent restenosis rate with that of historical diabetic controls. From January 2010 to December 2011, 44 consecutive diabetic patients (32 men; mean age 74±11 years) were treated with DEBs and enrolled in the study. The control group comprised 42 diabetic patients (23 men; mean age 76±7 years) treated with a conventional balloon for femoropopliteal ISR from 2008 to 2009. RESULTS: No significant differences in terms of clinical, angiographic, or procedural characteristics were observed between the study groups. Lesion length was 132±86 mm in the DEB group vs. 137±82 mm in the BA group. Procedural success, defined as a residual stenosis <30% in the restenotic segment (stent +5 mm at proximal and distal edges), was obtained in all treated lesions. At 1-year follow-up, 6 patients died (3 in each group), and 1 patient in the BA group underwent major amputation. Recurrent restenosis, assessed by angiography (66%) or ultrasound (34%), occurred in 8/41 (19.5%) patients in the DEB group vs. 28/39 (71.8%) in the BA group (p<0.001). Target lesion revascularization for symptomatic recurrent restenosis was performed in 6/44 (13.6%) patients in the DEB vs.13/42 (31.0%) in the BA group (p=0.045). CONCLUSION: Using DEB for treating femoropopliteal ISR led to a significant reduction in recurrent restenosis and repeat angioplasty at 1-year follow-up as compared to historical controls.
    [Abstract] [Full Text] [Related] [New Search]