These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Preoperative computer-based simulations for the correction of kyphotic deformities in ankylosing spondylitis patients. Author: Park YS, Kim HS, Baek SW, Oh JH. Journal: Spine J; 2014 Oct 01; 14(10):2420-4. PubMed ID: 24534395. Abstract: BACKGROUND CONTEXT: A preoperative plan is important to obtain appropriate balance of the sagittal plane in patients with kyphotic deformity. Previous methods to calculate the correction angle are inconvenient and complicated, whereas the method using computer simulations may be very effective and much simpler than existing methods. PURPOSE: To evaluate the efficacy of preoperative measurements using a computer simulation for corrective osteotomy for the surgical treatment of kyphosis caused by ankylosing spondylitis (AS). STUDY DESIGN: Retrospective clinical data analysis. PATIENT SAMPLE: The sample comprises 18 AS patients with fixed kyphotic deformity who underwent corrective osteotomies at our hospital between October 2007 and January 2010. OUTCOME MEASURES: Thoracic kyphosis, lumbar lordosis, and the sagittal vertical axis (SVA) of the spine were evaluated by preoperative computer simulation and radiologic measurement. Clinical assessments were performed according to the Bath Ankylosing Spondylitis Disease Activity Index (BASDAI), Bath Ankylosing Spondylitis Functional Index (BASFI), Short Form-36 (SF-36), and EuroQol-5 dimension (EQ-5D) before and after the surgery. METHODS: The coincidence between the preoperative computer simulation and postoperative radiologic parameters was evaluated. We also analyzed the changes derived from each clinical and radiologic measurement before and after the surgery. RESULTS: Mean thoracic kyphosis changed from 32.4° to 31.9°, mean lumbar lordosis was corrected from 11.5° to 26.9°, and the SVA was improved from 125.7 to 65.1 mm after surgery (p<.001). The correlation coefficients within groups between the computer simulations and radiologic parameters were 0.9, 0.6, and 0.7, showing significant congruency. Although BASDAI and BASFI did not significantly differ (p=.53 and p=.45, respectively), SF-36 and EQ-5D were significantly increased (p<.05 and p<.001, respectively). CONCLUSIONS: Comparisons of preoperative simulations and actual surgical outcomes showed significant coincidences; thus, evaluations through computer simulations before surgery are expected to help predict the level of correction possible after surgery and improve surgical planning.[Abstract] [Full Text] [Related] [New Search]