These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Comparative evaluation of impression accuracy of tilted and straight implants in All-on-Four technique.
    Author: Ehsani S, Siadat H, Alikhasi M.
    Journal: Implant Dent; 2014 Apr; 23(2):225-30. PubMed ID: 24614881.
    Abstract:
    PURPOSE: The aim of this in vitro study was to compare the accuracy of implant impressions in parallel and nonparallel implants of All-on-Four treatment plan. MATERIALS AND METHODS: A reference model containing 4 internal-connection implant analogs was fabricated according to All-on-Four treatment plan (2 anterior implants at 0 degree and 2 posterior implants at 30 degrees in relation to the perpendicular line). Twenty impressions of this model were made using open-tray impression technique. Impressions were poured with American Dental Association type 4 stone, and the positional accuracy of the implant replica heads in x-, y-, and z- axes was evaluated using a coordinate measuring machine. These measurements were compared with the obtained measurements from the reference model that served as control, and data were analyzed using independent test (α = 0.05). RESULTS: The results showed that the accuracy of the implant impressions did not show any significant difference between the tilted and straight implants except in y-coordinate (P = 0.012). CONCLUSION: Within the limitations of this study, the accuracy of the implant impressions did not differ for different implant angulations in All-on-Four treatment plan.
    [Abstract] [Full Text] [Related] [New Search]