These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Usefulness of adding SPECT/CT to 99mTc-hexamethylpropylene amine oxime (HMPAO)-labeled leukocyte imaging for diagnosing prosthetic joint infections. Author: Kim HO, Na SJ, Oh SJ, Jung BS, Lee SH, Chang JS, Bin SI, Ryu JS. Journal: J Comput Assist Tomogr; 2014; 38(2):313-9. PubMed ID: 24625603. Abstract: OBJECTIVE: This study evaluated the usefulness of adding single-photon emission computed tomography (SPECT)/computed tomography (CT) (SPECT/CT) to technetium Tc 99m (Tc) hexamethylpropylene amine oxime (HMPAO)-labeled leukocyte imaging for diagnosing infections in hip or knee joint prostheses. METHODS: The Tc-HMPAO-labeled leukocyte scans of 164 patients (71 with hip prostheses and 93 with knee prostheses) with clinically suspected prosthetic infections were reviewed retrospectively. Planar images were taken 4 to 6 and 21 to 26 hours after injecting the labeled leukocytes and SPECT/CT images were obtained 4 to 6 hours after the injection. The final diagnosis of infection was based on pathologic findings (n = 70), bacteriological data (n = 61), or clinical follow-up (n = 33). RESULTS: Of the 164 patients, 89 patients had a diagnosis of prosthetic joint infections. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of the planar images alone were 82.0%, 88.0%, 89.0%, 80.5%, and 84.8%, respectively. When the planar images were combined with SPECT, the sensitivity, specificity, PPV, NPV, and diagnostic accuracy were 91.0%, 88.0%, 90.0%, 89.2%, and 89.6%, respectively. When the planar images were combined with SPECT/CT, these values increased further to 93.3%, 93.3%, 94.3%, 92.1%, and 93.3%, respectively. Adding CT to SPECT resulted in a greater increase in sensitivity and specificity for hip prosthesis infections than for knee prosthesis infections. SPECT/CT mainly contributed by precisely localizing the anatomical site of the active inflammatory lesion and by delineating the extent of the lesion after diagnosis with SPECT. CONCLUSIONS: Single-photon emission computed tomography/CT combined with Tc-HMPAO-labeled leukocyte imaging was useful for diagnosing prosthesis infections, particularly in hip prosthesis infections, as it improved diagnostic accuracy and provided anatomical localization data.[Abstract] [Full Text] [Related] [New Search]