  • Title: Standard Trabeculectomy and Ex-PRESS Miniature Glaucoma Shunt: A Comparative Study and Literature Review.
    Author: Moisseiev E, Zunz E, Tzur R, Kurtz S, Shemesh G.
    Journal: J Glaucoma; 2015 Aug; 24(6):410-6. PubMed ID: 24633088.
    Abstract:
    PURPOSE: The aim of this study was to compare the efficacy and safety between standard trabeculectomy and the Ex-PRESS shunt implantation. METHODS: A retrospective review of the records of 100 eyes of 100 patients who underwent trabeculectomy or Ex-PRESS shunt implantation between July 2010 and June 2012 was conducted. Of these, 61 (61%) eyes underwent trabeculectomy and 39 (39%) eyes underwent Ex-PRESS shunt implantation. Demographic information, glaucoma type, surgical details, preoperative, and postoperative data including intraocular pressure (IOP), number of medications, reoperation, and occurrence of any complications were recorded. RESULTS: No differences in IOP reduction or number of postoperative IOP-lowering medications were demonstrated between the 2 procedures. Success rates were 86.9% for trabeculectomy and 84.6% for Ex-PRESS shunt. Rates of failure and hypotony were not significantly different between the groups. No parameter was correlated with success or failure of any procedure. CONCLUSIONS: Standard trabeculectomy and Ex-PRESS shunt have similar efficacy and safety profiles. As the Ex-PRESS shunt is considerably more expensive, its use may be unjustified, especially as a primary procedure.