These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Use of the 6-min walk distance to identify variations in treatment benefits from implantable cardioverter-defibrillator and amiodarone: results from the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial).
    Author: Fishbein DP, Hellkamp AS, Mark DB, Walsh MN, Poole JE, Anderson J, Johnson G, Lee KL, Bardy GH, SCD-HeFT Investigators.
    Journal: J Am Coll Cardiol; 2014 Jun 17; 63(23):2560-2568. PubMed ID: 24727258.
    Abstract:
    OBJECTIVES: The purpose of this study was to determine if 6-min walk test data assists in treatment decisions for patients with heart failure. BACKGROUND: In the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial), a pre-specified subgroup analysis showed that patients with New York Heart Association functional class III symptoms did not benefit from implantable cardioverter-defibrillator (ICD) therapy and appeared to be harmed by amiodarone, whereas New York Heart Association functional class II patients obtained significant survival benefit from ICD. We postulated that a more objective measure of functional capacity, such as 6-min walk (6MW) distance, might provide a better tool for selecting these preventive therapies. METHODS: A 6MW test was performed before randomization in 2,397 patients. Median follow-up was 45.5 months. All-cause mortality was the primary endpoint, with cause-specific mortality (heart failure, arrhythmic) examined in secondary analyses. RESULTS: The hazard ratios (HRs) for ICD therapy compared to placebo were estimated within tertiles of baseline 6MW distance: HR: 0.42 (95% confidence interval [CI]: 0.26 to 0.66) for 6MW distance >386 m (top tertile); HR: 0.57 (95% CI: 0.39 to 0.83) for 6MW distance 288 to 386 m (middle tertile); and HR: 1.02 (95% CI: 0.75 to 1.39) for 6MW distance <288 m (bottom tertile). The corresponding HRs for amiodarone compared to placebo were 0.68 (95% CI: 0.46 to 1.02) for the top, 0.86 (95% CI: 0.61 to 1.21) for the middle, and 1.56 (95% CI: 1.17 to 2.09) for the bottom tertile. The 6MW distance was inversely related to heart failure-related mortality but not to arrhythmic mortality. ICD therapy reduced arrhythmic mortality in the top 2 tertiles of 6MW, but had no effect on heart failure mortality. CONCLUSIONS: A baseline 6MW distance <288 m identified a subgroup of SCD-HeFT patients who were harmed by amiodarone therapy and did not benefit from ICD. (Sudden Cardiac Death in Heart Failure Trial [SCD-HeFT]; NCT00000609).
    [Abstract] [Full Text] [Related] [New Search]