These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Translation and validation of the Chinese version of the Quality OF Life Radiation Therapy Instrument and the Head & Neck Module (QOL-RTI/H&N). Author: Chen XL, Qiu ZW, Gu MF, Su Y, Liu LZ, Liu Y, Mo CW, Xu Q, Sun J, Li DH. Journal: Health Qual Life Outcomes; 2014 Apr 14; 12():51. PubMed ID: 24731442. Abstract: BACKGROUND: To translate and validate the Chinese version of the Quality Of Life Radiation Therapy Instrument and the Head & Neck Module (QOL-RTI/H&N), a disease-specific scale to measure quality of life (QOL) for patients with head and neck cancer (HNC) who received radiotherapy. METHODS: The QOL-RTI/H&N was translated and validated according to the standard process: a translation and back-translation procedure, pilot testing and a validation study. HNC patients were enrolled from the Cancer Center of Sun Yat-sen University and assessed using the QOL-RTI/H&N, QLQ-C30 and QLQ-H&N35. Reliability (internal consistency reliability, split-half reliability and test-retest reliability), validity (content validity, construct validity, criterion validity and discriminant validity), and responsiveness analysis were performed to evaluate the psychometric characteristics of the QOL-RTI/H&N. RESULTS: A total of 238 patients (99.2%) completed the questionnaire. Item RTI23 had 16.0% missing data. Other items had low percentages of missing data (0.4% or 0.8%) or no missing data. The average time to finish the scale was 9.8 minutes. Cronbach's alpha of the domains ranged from 0.41 to 0.77. The split-half reliability coefficients ranged from 0.43 to 0.77. All of the intra-class correlation coefficients were equal to or greater than 0.8. All of the item-own domain correlation coefficients were greater than those of the item-other domain. Confirmatory factor analysis showed that Comparative Fit Index, Normed Fit Index and Non-Normed Fit Index were equal to 1.00. Root Mean Square Error of Approximation was 0.01, with 90% CI (0.00, 0.10). The domain scores of the QOL-RTI/H&N were significantly correlated with those of the QLQ-C30 or QLQ-H&N3. All domain scores of patients in different radiotherapy stages were statistically significant (P < 0.05), apart from the speech domain. CONCLUSIONS: The Chinese version of the QOL-RTI/H&N is a valid, reliable and responsive scale to measure QOL in HNC patients and can be used to assess the effects of radiotherapy treatment on these patients.[Abstract] [Full Text] [Related] [New Search]