These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Two-year clinical experience with the CyPass micro-stent: safety and surgical outcomes of a novel supraciliary micro-stent. Author: Höh H, Grisanti S, Grisanti S, Rau M, Ianchulev S. Journal: Klin Monbl Augenheilkd; 2014 Apr; 231(4):377-81. PubMed ID: 24771171. Abstract: PURPOSE: The aim of this study was to evaluate through 2 postoperative years the clinical outcomes associated with a novel supraciliary micro-stent for the surgical treatment of open-angle glaucoma (OAG) when implanted in conjunction with cataract surgery. PATIENTS AND METHOD: In a multicenter, prospective, consecutive case series, 136 subjects (136 eyes) with OAG and requiring cataract surgery with 24-month postoperative data were included. A combined phacoemulsification procedure, with intraocular lens insertion and CyPass Micro-Stent implantation into the supraciliary space of the study eye, was performed. At baseline, all subjects were on glaucoma medication with either uncontrolled intraocular pressure (IOP; ≥ 21 mmHg, Cohort 1, n=51) or controlled IOP (<21 mmHg, Cohort 2, n=85). Glaucoma medications were stopped postoperatively, but could be restarted if needed, at the investigator's discretion. Device-related adverse events, postoperative IOP, best corrected distance visual acuity (BCDVA), and number of IOP-lowering medications were recorded. RESULTS: The micro-stent was successfully implanted in all eyes. At 24 months, 82 subjects remained in the study. No sight-threatening adverse events occurred. The most common adverse events were transient hypotony (15.4%) and micro-stent obstruction (8.8%), typically due to iris tissue overgrowth. Fifteen subjects (11%) required secondary incisional glaucoma surgery. For Cohort 1 (n=23), mean ± SD IOP was 15.8 ± 3.8 mmHg after 24 months (change, -37% ± 19%). Mean IOP decrease from baseline was statistically significant (p<0.0001) at months 6, 12, and 24. For Cohort 2 (n=59), mean ± SD IOP at 24 months was 16.1 ± 3.2 mmHg (change, 0% ± 28%). Mean decrease from baseline was statistically significant at months 6 (p=0.0188) and 12 (p=0.0356). At 24 months, the mean ± SD number of medications was 1.0 ± 1.1 in Cohort 1 and 1.1 ± 1.1 in Cohort 2. Mean decrease from baseline medication use was statistically significant at months 6 (p<0.001), 12 (p<0.001), and 24 (p=0.0265) in Cohort 1, and at months 6, 12, and 24 (all p<0.0001) in Cohort 2. CONCLUSIONS: CyPass Micro-Stent implantation, in combination with cataract surgery, was associated with minimal complications while substantially lowering IOP and/or use of IOP-lowering medications.[Abstract] [Full Text] [Related] [New Search]