These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Turn-off-on chemiluminescence determination of cyanide.
    Author: Han S, Wang J, Jia S.
    Journal: Luminescence; 2015 Feb; 30(1):38-43. PubMed ID: 24804930.
    Abstract:
    A flow injection chemiluminescence (FI-CL) method was developed for the determination of cyanide (CN(-) ) based on the recovered CL signal by Cu(2+) inhibiting a glutathione (GSH)-capped CdTe quantum dot (QD) and hydrogen peroxide system. In an alkaline medium, strong CL signals were observed from the reaction of CdTe QDs and H2O2 , and addition of Cu(2+) could cause significant CL inhibition of the CdTe QDs-H2O2 system. In the presence of CN(-) , Cu(2+) can be removed from the surface of CdTe QDs via the formation of particularly stable [Cu(CN)n ]((n-1)-) species, and the CL signal of the CdTe QDs-H2O2 system was efficiently recovered. Thus, the CL signals of CdTe QDs-H2O2 system were turned off and turned on by the addition of Cu(2+) and CN(-) , respectively. Further, the results showed that among the tested ions, only CN(-) could recover the CL signal, which suggested that the CdTe QDs-H2O2 -Cu(2+) CL system had highly selectivity for CN(-) . Under optimum conditions, the CL intensity and the concentration of CN(-) show a good linear relationship in the range 0.0-650.0 ng/mL (R(2)  = 0.9996). The limit of detection for CN(-) was 6.0 ng/mL (3σ). This method has been applied to detect CN(-) in river water and industrial wastewater with satisfactory results.
    [Abstract] [Full Text] [Related] [New Search]