These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Technical tips: dualplate fixation technique for comminuted proximal humerus fractures.
    Author: Choi S, Kang H, Bang H.
    Journal: Injury; 2014 Aug; 45(8):1280-2. PubMed ID: 24813097.
    Abstract:
    The authors report dualplate fixation technique for providing stable fixation in comminuted proximal humerus fractures. This technique has been used for proximal humerus fractures with metaphyseal comminution and provides excellent anatomical reduction and neck shaft angle (NSA). The recently locking plate is clinically more widely used due to its small size, low rigidity, high elasticity, and biomechanical properties such as fixed initial angle and rotational stability. However, in severely comminuted complex type proximal metaphyseal humerus fractures, the use of locking plate alone does not provide stable fixation, leading to complications such as varus collapse, anterior-posterior angulation, screw cutout, nonunion, malunion, and metal failure. Therefore, a more robust and enhanced fixation method, the dual plating technique using the locking compression plate (Proximal Humeral Internal Locking System and Variable Angle Locking Compression Plate) was developed.
    [Abstract] [Full Text] [Related] [New Search]