These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Comparison of biolimus A9-eluting (Nobori) and everolimus-eluting (Promus Element) stents in patients with de novo native long coronary artery lesions: a randomized Long Drug-Eluting Stent V trial. Author: Lee JY, Park DW, Kim YH, Ahn JM, Kim WJ, Kang SJ, Lee SW, Lee CW, Park SW, Yun SC, Yang TH, Lee BK, Lee NH, Yang JY, Shin WY, Park HS, Kim KS, Hur SH, Lee SY, Park JS, Choi YS, Lee SU, Her SH, Park SJ. Journal: Circ Cardiovasc Interv; 2014 Jun; 7(3):322-9. PubMed ID: 24823426. Abstract: BACKGROUND: Procedural and clinical outcomes still remain unfavorable for patients with long coronary lesions who undergo percutaneous coronary intervention. The current study, therefore, evaluated 2 innovative drug-eluting stents for the management of long-lesion coronary artery disease. METHODS AND RESULTS: This randomized, multicenter, prospective trial, called the Long Drug-Eluting Stent (LONG-DES) V trial, compared the biodegradable polymer-based biolimus A9-eluting stent (BES) and the durable polymer-based platinum chromium everolimus-eluting stent (PtCr-EES) in 500 patients with long (≥ 25 mm) coronary lesions. The primary end point of the trial was in-segment late luminal loss at the 9-month angiographic follow-up. The BES and PtCr-EES groups had similar baseline characteristics, with a slightly shorter lesion length in the BES group versus the PtCr-EES group (29.24 ± 12.17 versus 32.27 ± 13.84 mm; P = 0.016). In-segment late luminal loss was comparable between the 2 groups at the 9-month angiographic follow-up (BES, 0.14 ± 0.38 versus PtCr-EES, 0.11 ± 0.37 mm; difference, 0.031; 95% confidence interval, -0.053 to 0.091; P = 0.03 for a noninferiority margin of 0.11, P = 0.45 for superiority), as was in-stent late luminal loss (0.20 ± 0.41 versus 0.24 ± 0.38 mm; P = 0.29). The incidence of in-segment (6.1% versus 4.9%; P = 0.63) and in-stent (3.7% versus 4.9%; P = 0.59) binary restenosis was also similar between the groups. There was no significant between-group difference in the rate of composite outcome of death, myocardial infarction, and target vessel revascularization (41, 16.7% in BES versus 42, 16.5% in PtCr-EES; P=0.94). CONCLUSIONS: BES and PtCr-EES implantation showed analogous angiographic and clinical outcomes for patients with de novo long coronary lesions. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01186120.[Abstract] [Full Text] [Related] [New Search]