These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Femoral bone and cartilage wear is predictable at 0° and 90° in the osteoarthritic knee treated with total knee arthroplasty. Author: Nam D, Lin KM, Howell SM, Hull ML. Journal: Knee Surg Sports Traumatol Arthrosc; 2014 Dec; 22(12):2975-81. PubMed ID: 24839078. Abstract: PURPOSE: Kinematically aligned total knee arthroplasty (TKA) positions the femoral component at the natural angle and level of the distal (0°) and posterior (90°) joint line. This technique applies referencing guides at 0° and 90° that are adjusted to compensate for wear and kerf and perform resections equal in thickness to the femoral component. Knowing whether femoral bone and cartilage wear is predictable would assist in establishing general guidelines for adjusting the resection level of these two referencing guides. This study tests the hypothesis that femoral bone and cartilage wear is predictable at 0° and 90° in the varus and valgus osteoarthritic knee treated with TKA. METHODS: The study consists of 205 patients and 208 knees with Kellgren-Lawrence Grade 3 or 4 osteoarthritis and treated with a TKA. Each knee had a narrow slice (2 mm) preoperative 1.5 tesla magnetic resonance image in the sagittal plane. Femoral bone and cartilage wear at 0° and 90° was computed from best-fit circles superimposed on the peripheral boundary of the subchondral bone on the medial and lateral femoral condyles. RESULTS: Overall, 99.5% of knees had minimal bone wear (<1 mm) at 0° and 90°. In the 74% (154 of 208) of knees with a varus deformity, 92% at 0° and 2 % at 90° had >1 mm cartilage wear on the medial femoral condyle. In the 26% (54 of 208) of knees with a valgus deformity, 78% at 0° and 55% at 90° had ≥1 mm cartilage wear on the lateral femoral condyle. CONCLUSIONS: As a general guideline, adjustment for femoral bone wear is rarely required when performing kinematically aligned TKA. Most osteoarthritic knees require adjustment of the distal referencing guide to compensate for cartilage wear on the medial femoral condyle in the varus knee and the lateral femoral condyle in the valgus knee. Adjustment of the posterior referencing guide is required in about half of valgus osteoarthritic knees to compensate for lateral cartilage wear at 90°. Knowing that bone wear is rare and cartilage wear is predictable in varus and valgus Kellgren-Lawrence Grade 3 or 4 osteoarthritic knees helps establish general guidelines for adjusting the distal and posterior femoral referencing guides to restore the natural angle and level of the femoral joint lines when performing kinematically aligned TKA with generic instruments. LEVEL OF EVIDENCE: IV.[Abstract] [Full Text] [Related] [New Search]