These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Determination of domperidone in human plasma using high performance liquid chromatography with fluorescence detection for clinical application.
    Author: Yoshizato T, Tsutsumi K, Kotegawa T, Imai H, Nakano S.
    Journal: J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Jun 15; 961():86-90. PubMed ID: 24869944.
    Abstract:
    A simple and reliable method for the determination of domperidone in human plasma has been developed. Plasma samples (1mL) were pre-purified by a solid-phase extraction with Bond Elut(®) C18. The separation was achieved with XBridge™ C18 column (150mm×4.6mm i.d., 5μm) at 40°C. The mobile phase was a mixture of acetonitrile and 10mM ammonium acetate buffer (36:64, v/v), adjusted to pH 9.4 with 20% ammonium solution at a flow rate of 1.0mL/min. The peak was detected using fluorescence detector at excitation 282nm and emission 328nm. Retention times for domperidone and internal standard (propranolol) were 8.3min and 11.2min, respectively. The method showed a good linearity (r>0.999), precision (relative standard deviations <10.6%), and extraction recovery (85.7-99.7%) over a concentration of 1-100ng/mL. The lower limit of quantification (LLOQ) was 1.0ng/mL. This proposed method was successfully applied to a pharmacokinetic interaction study of domperidone in healthy Japanese volunteers.
    [Abstract] [Full Text] [Related] [New Search]