These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Basics of sterile compounding: compounding by weight versus compounding by volume.
    Author: Thoma L.
    Journal: Int J Pharm Compd; 2014; 18(2):131-4. PubMed ID: 24881117.
    Abstract:
    In compounding small volumes of sterile preparations, it is generally acceptable to use volumetric measurements. However, when compounding larger volumes or when the sterile preparation has a low concentration, it is best to compound by weight for greater accuracy. This article provides the procedures that can be followed when compounding by weight as compared to volume and provides an example of the steps involved in compounding 18.5 liters of progesterone 100 mg/mL injection.
    [Abstract] [Full Text] [Related] [New Search]