These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Long-term outcomes and sac volume shrinkage after endovascular popliteal artery aneurysm repair. Author: Piazza M, Menegolo M, Ferrari A, Bonvini S, Ricotta JJ, Frigatti P, Grego F, Antonello M. Journal: Eur J Vasc Endovasc Surg; 2014 Aug; 48(2):161-8. PubMed ID: 24913684. Abstract: OBJECTIVES: The aim was to evaluate long-term outcomes and sac volume shrinkage after endovascular popliteal artery aneurysm repair (EVPAR). METHODS: This study was a retrospective review of all EVPAR cases between 1999 and 2012. Sac volume shrinkage, long-term patency, limb salvage, and survival were evaluated using Kaplan-Meier estimates. The association of anatomical and clinical characteristics with patency was evaluated using multivariate analysis. RESULTS: Forty-six EVPAR were carried out in 42 patients (mean age 78 years, 86% male; mean sac volume 45.5 ± 3.5 mL). In 93% of cases (n = 43) the procedure was elective, while in 7% of cases it was for rupture (n = 2) or acute thrombosis (n = 1). Of the 43 patients who underwent elective repair, 58% were asymptomatic and 42% symptomatic (14 claudication, 3 rest pain, and 1 compression symptoms). Technical success was 98%. Mean duration of follow-up was 56 ± 21 months. Primary patency at 1, 3, and 5 years was 82% (SE 2), 79% (SE 4), and 76% (SE 4), while secondary patency was 90% (SE 5), 85% (SE 4), and 82% (SE 1) respectively; at 5 years there was 98% limb salvage and an 84% survival rate. During follow-up 11 limbs had stent graft failure: six required conversion, one underwent amputation, and four continued with mild claudication. Of those with graft failure, 63% (7/11) occurred within the first year of follow-up. The mean aneurysm sac volume shrinkage between preoperative and 5-year post-procedure measurement was significant (45.5 ± 3.5 mL vs. 23.0 ± 5.0 mL; p < .001). Segment coverage >20 cm was a negative predictor for patency (HR 2.76; 95% CI 0.23; p = .032). CONCLUSIONS: EVPAR provides successful aneurysm exclusion with good long-term patency, excellent limb salvage, and survival rates. Close surveillance is nevertheless required, particularly during the first postoperative year. Patients requiring long segment coverage (>20 cm) may be at increased risk for failure.[Abstract] [Full Text] [Related] [New Search]