Search MEDLINE/PubMed
Title: A highly sensitive NADH sensor based on a mycelium-like nanocomposite using graphene oxide and multi-walled carbon nanotubes to co-immobilize poly(luminol) and poly(neutral red) hybrid films. Author: Chiang Lin K, Yu Lai S, Ming Chen S. Journal: Analyst; 2014 Aug 21; 139(16):3991-8. PubMed ID: 24922539. Abstract: Hybridization of poly(luminol) (PLM) and poly(neutral red) (PNR) has been successfully performed and further enhanced by a conductive and steric hybrid nanotemplate using graphene oxide (GO) and multi-walled carbon nanotubes (MWCNTs). The morphology of the PLM-PNR-MWCNT-GO mycelium-like nanocomposite is studied by SEM and AFM and it is found to be electroactive, pH-dependent, and stable in the electrochemical system. It shows electrocatalytic activity towards NADH with a high current response and low overpotential. Using amperometry, it has been shown to have a high sensitivity of 288.9 μA mM(-1) cm(-2) to NADH (Eapp. = +0.1 V). Linearity is estimated in a concentration range of 1.33 × 10(-8) to 1.95 × 10(-4) M with a detection limit of 1.33 × 10(-8) M (S/N = 3). Particularly, it also shows another linear range of 2.08 × 10(-4) to 5.81 × 10(-4) M with a sensitivity of 151.3 μA mM(-1) cm(-2). The hybridization and activity of PLM and PNR can be effectively enhanced by MWCNTs and GO, resulting in an active hybrid nanocomposite for determination of NADH.[Abstract] [Full Text] [Related] [New Search]