These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Added value of shear-wave elastography for evaluation of breast masses detected with screening US imaging.
    Author: Lee SH, Chang JM, Kim WH, Bae MS, Seo M, Koo HR, Chu AJ, Gweon HM, Cho N, Moon WK.
    Journal: Radiology; 2014 Oct; 273(1):61-9. PubMed ID: 24955927.
    Abstract:
    PURPOSE: To evaluate the additional value of shear-wave elastography (SWE) to B-mode ultrasonography (US) and to determine an appropriate guideline for the combined assessment of screening US-detected breast masses. MATERIALS AND METHODS: This study was conducted with institutional review board approval, and written informed consent was obtained. From March 2010 to February 2012, B-mode US and SWE were performed in 159 US-detected breast masses before biopsy. For each lesion, Breast Imaging Reporting and Data System (BI-RADS) category on B-mode US images and the maximum stiffness color and elasticity values on SWE images were assessed. A guideline for adding SWE data to B-mode US was developed with the retrospective cohort to improve diagnostic performance in sensitivity and specificity and was validated in a distinct prospective cohort of 207 women prior to biopsy. RESULTS: Twenty-one of 159 masses in the development cohort and 12 of 207 breast masses in the validation cohort were malignant. In the development cohort, when BI-RADS category 4a masses showing a dark blue color or a maximum elasticity value of 30 kPa or less on SWE images were downgraded to category 3, specificity increased from 9.4% (13 of 138) to 59.4% (82 of 138) and 57.2% (79 of 138) (P < .001), respectively, without loss in sensitivity (100% [21 of 21]). In the validation cohort, specificity increased from 17.4% (34 of 195) to 62.1% (121 of 195) and 53.3% (104 of 195) (P < .001) respectively, without loss in sensitivity (91.7% [11 of 12]). CONCLUSION: The addition of SWE to B-mode US improved diagnostic performance with increased specificity for screening US-detected breast masses. BI-RADS category 4a masses detected at US screening that showed a dark blue color or a maximum elasticity value of 30 kPa or less on SWE images can be safely followed up instead of performing biopsy.
    [Abstract] [Full Text] [Related] [New Search]