These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: 1-1-12 one-step wash-in scheme for desflurane-nitrous oxide low-flow anesthesia: rapid and predictable induction.
    Author: Sathitkarnmanee T, Tribuddharat S, Suttinarakorn C, Nonlhaopol D, Thananun M, Somdee W, Theerapongpakdee S.
    Journal: Biomed Res Int; 2014; 2014():867504. PubMed ID: 24991571.
    Abstract:
    BACKGROUND: We propose a 1-1-12 wash-in scheme for desflurane-nitrous oxide (N2O) low-flow anesthesia. The objective of our study was to determine the time to achieve alveolar concentration of desflurane (FAD) at 1, 2, 3, 4, 5, and 6%. METHODS: We enrolled 106 patients scheduled for elective surgery under general anesthesia. After induction and intubation, wash-in was started with a fresh gas flow (FGF) of N2O : O2 1 : 1 L min(-1) and vaporizer concentration of desflurane (FD) of 12%. Ventilation was controlled to maintain PACO2 at 30-35 mmHg. RESULTS: The FAD rose rapidly from 0 to 4% in 2 min in a linear manner in 0.5 min increments. An FAD of 6% was achieved in 4 min in a linear fashion from FAD of 4% but in 1 min increments. An FAD of 1 to 6% occurred at 0.6, 1, 1.5, 2, 3, and 4 min. Heart rate during wash-in showed a statistically, albeit not clinically, significant pattern of increase. By contrast, blood pressure slightly decreased during this period. CONCLUSIONS: We developed a 1-1-12 wash-in scheme using a FGF of N2O : O2 1 : 1 L min(-1) and FD of 12% for desflurane-nitrous oxide low-flow anesthesia. A respective FAD of 1, 2, 3, 4, 5, and 6% can be expected at 0.6, 1, 1.5, 2, 3, and 4 min.
    [Abstract] [Full Text] [Related] [New Search]