These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Percutaneous mitral valve repair for mitral regurgitation in high-risk patients: results of the EVEREST II study. Author: Glower DD, Kar S, Trento A, Lim DS, Bajwa T, Quesada R, Whitlow PL, Rinaldi MJ, Grayburn P, Mack MJ, Mauri L, McCarthy PM, Feldman T. Journal: J Am Coll Cardiol; 2014 Jul 15; 64(2):172-81. PubMed ID: 25011722. Abstract: BACKGROUND: The EVEREST II (Endovascular Valve Edge-to-Edge REpair STudy) High-Risk registry and REALISM Continued Access Study High-Risk Arm are prospective registries of patients who received the MitraClip device (Abbott Vascular, Santa Clara, California) for mitral regurgitation (MR) in the United States. OBJECTIVES: The purpose of this study was to report 12-month outcomes in high-risk patients treated with the percutaneous mitral valve edge-to-edge repair. METHODS: Patients with grades 3 to 4+ MR and a surgical mortality risk of ≥12%, based on the Society of Thoracic Surgeons risk calculator or the estimate of a surgeon coinvestigator following pre-specified protocol criteria, were enrolled. RESULTS: In the studies, 327 of 351 patients completed 12 months of follow-up. Patients were elderly (76 ± 11 years of age), with 70% having functional MR and 60% having prior cardiac surgery. The mitral valve device reduced MR to ≤2+ in 86% of patients at discharge (n = 325; p < 0.0001). Major adverse events at 30 days included death in 4.8%, myocardial infarction in 1.1%, and stroke in 2.6%. At 12 months, MR was ≤2+ in 84% of patients (n = 225; p < 0.0001). From baseline to 12 months, left ventricular (LV) end-diastolic volume improved from 161 ± 56 ml to 143 ± 53 ml (n = 203; p < 0.0001) and LV end-systolic volume improved from 87 ± 47 ml to 79 ± 44 ml (n = 202; p < 0.0001). New York Heart Association functional class improved from 82% in class III/IV at baseline to 83% in class I/II at 12 months (n = 234; p < 0.0001). The 36-item Short Form Health Survey physical and mental quality-of-life scores improved from baseline to 12 months (n = 191; p < 0.0001). Annual hospitalization rate for heart failure fell from 0.79% pre-procedure to 0.41% post-procedure (n = 338; p < 0.0001). Kaplan-Meier survival estimate at 12 months was 77.2%. CONCLUSIONS: The percutaneous mitral valve device significantly reduced MR, improved clinical symptoms, and decreased LV dimensions at 12 months in this high-surgical-risk cohort. (Endovascular Valve Edge-to-Edge REpair STudy [EVERESTIIRCT]; NCT00209274).[Abstract] [Full Text] [Related] [New Search]