These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Effect of microbiological testing on subsequent mid-infrared milk component analysis of the same milk sample.
    Author: Wojciechowski KL, Melilli C, Barbano DM.
    Journal: J Dairy Sci; 2014 Sep; 97(9):5885-97. PubMed ID: 25022674.
    Abstract:
    Our objectives were to determine if mixing and sampling of a raw milk sample at 4°C for determination of total bacteria count (TBC) and if incubation at 14°C for 18h and sampling for a preliminary incubation (PI) count influenced the accuracy of subsequent fat, protein, or lactose measurement by mid-infrared (IR) analysis of milk from the same sample container due to either nonrepresentative sampling or the presence of microbial metabolites produced by microbial growth in the milk from the incubation. Milks of 4 fat levels (2.2, 3, 4, and 5%) reflected the range of fat levels encountered in producer milks. If the portion of milk removed from a cold sample was not representative, then the effect on a milk component test would likely be larger as fat content increases. Within the milks at each fat level, 3 treatments were used: (1) 20 vials of the same milk sampled for testing TBC using a BactoScan FC and then used for a milk component test; (2) 20 vials for testing TBC plus PI count followed by component test; and (3) 20 vials to run for IR component test without a prior micro sampling and testing. This was repeated in 3 different weeks using a different batch of milk each week. No large effect on the accuracy of component milk testing [IR fat B (carbon hydrogen stretch) and fat A (carbonyl stretch)] due to the cold milk sample handling and mixing procedures used for TBC was detected, confirming the fact that the physical removal of milk from the vial by the BactoScan FC (Foss Electric, Hillerød, Denmark) was a representative portion of the milk. However, the representativeness of any other sampling procedure (manual or automated) of a cold milk sample before running milk component testing on the same container of milk should be demonstrated and verified periodically as a matter of routine laboratory quality assurance. Running TBC with a BactoScan FC first and then IR milk analysis after had a minimal effect on milk component tests by IR when milk bacteria counts were within pasteurized milk ordinance limits of <100,000 cfu/mL. Running raw milk PI counts (18h of incubation at 13-14°C) with the BactoScan FC before milk component testing by IR milk analysis had an effect on component tests. The effect was largest on fat test results and would decrease the accuracy of milk payment testing on individual producer milks. The effect was most likely due to the absorption of light by bacterial metabolites resulting from microbial growth or other chemical degradation processes occurring in the milk during the PI count incubation, not by the sampling procedure of the BactoScan. The direction of the effect on component test results will vary depending on the bacteria count and the type of bacteria that grew in the milk, and this could be different in every individual producer milk sample.
    [Abstract] [Full Text] [Related] [New Search]