These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Amyloid-β 42/40 cerebrospinal fluid concentration ratio in the diagnostics of Alzheimer's disease: validation of two novel assays. Author: Lewczuk P, Lelental N, Spitzer P, Maler JM, Kornhuber J. Journal: J Alzheimers Dis; 2015; 43(1):183-91. PubMed ID: 25079805. Abstract: BACKGROUND: The increasing role of cerebrospinal fluid (CSF) biomarkers in the early diagnosis of Alzheimer's disease (AD) is reflected in recently published diagnostic and/or research criteria. A growing body of evidence suggests better diagnostic performance of the amyloid-β (Aβ)42/40 CSF concentration ratio compared to the Aβ42 concentration alone. OBJECTIVE: (a) to analytically validate two novel ELISAs capable to measure Aβ1-40 and Aβ1-42 in the CSF, and (b) to compare the diagnostic accuracies of Aβ1-42 and Aβ42/40 ratio. METHODS: In this study, (a) the novel Aβ1-40 and Aβ1-42 ELISAs (IBL International GmbH, Hamburg, Germany) have been analytically validated, and (b) a clinical study has been performed comparing the diagnostic performance of the CSF Aβ42/40 concentration ratio and the CSF Aβ42 concentration. RESULTS: In the analytical part of the study, only marginal cross-reactivity (Aβ1-42 versus Aβ1-40) was observed; recoveries were in the range of 85-100% for the samples diluted 1 : 20-1 : 640 (Aβ1-40), and 92-104% for the samples diluted 1 : 20-1 : 320 (Aβ1-42). For Aβ1-40, the intra-assay imprecision was 2.1%, the inter-assay imprecision was 4.4%, and the inter-lot imprecision was 5.4 %. For Aβ1-42, the numbers were 3.1%, 6.2%, and 6.9%, respectively. The goodness of the fit of the average standard curves was >0.99 for both assays, and the imprecision of the optical densities in ten repetitions of the standard curves was ≤5% for all standards. In the clinical part, at the cut off value 691 pg/mL, Aβ1-42 showed sensitivity and specificity of 69.3% and 88.9%, respectively, whereas at the cut off value 0.06, the Aβ42/40 ratio showed significantly improved performance with sensitivity and specificity of 93.3% and 100%, respectively. The area under the ROC curve for Aβ42/40 (0.974) was highly significantly larger compared to Aβ1-42 concentration ROC curve (0.827, p < 0.0001). CONCLUSIONS: (a) the novel Aβ1-40 and Aβ1-42 ELISA assays characterize with very good analytical performance; (b) we reconfirm that the CSF Aβ42/40 concentration ratio shows significantly better diagnostic performance compared to the CSF Aβ1-42 concentration alone.[Abstract] [Full Text] [Related] [New Search]