These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Navigated three-dimensional T1-weighted gradient-echo sequence for gadoxetic acid liver magnetic resonance imaging in patients with limited breath-holding capacity. Author: Yoon JH, Lee JM, Lee ES, Baek J, Lee S, Iwadate Y, Han JK, Choi BI. Journal: Abdom Imaging; 2015 Feb; 40(2):278-88. PubMed ID: 25112454. Abstract: PURPOSE: To determine whether a navigator-gated three-dimensional T1-weighted gradient-echo sequence (T1W-GRE, navigated LAVA) can improve diagnostic performance for the detection of focal liver lesions (FLLs) compared to standard breath-hold (BH) T1W-GRE breath-hold LAVA (BH-LAVA) during the hepatobiliary phase (HBP) of gadoxetic acid liver magnetic resonance imaging (MRI) in patients with limited breath-holding capacity. MATERIALS AND METHODS: This retrospective study was approved by our institutional review board and the requirement for informed consent was waived. We included 372 patients who underwent liver MRI including both navigated LAVA and BH-LAVA sequences. Overall image quality of the two HBP image sets was compared. In patients with limited breath-holding capacity, diagnostic performances in detecting FLLs on the two HBP images were compared using jackknife-alternative free-response receiver-operating characteristic (JAFROC) analysis by two reviewers. RESULTS: There were 13 cases (13/372; 3.5%) of image acquisition failure using the navigated LAVA sequence due to severe irregular breathing, and 50 of 359 patients had limited breath-holding capacity. In these patients, overall image quality of navigated LAVA (2.78 ± 0.95) was significantly better than that of BH-LAVA (2.42 ± 0.81, P < 0.005), and both readers showed significantly higher JAFROC figure-of-merit values with navigated LAVA compared to BH-LAVA (0.94 and 0.86 in reviewer 1, respectively; 0.89 and 0.83 in reviewer 2, respectively, P < 0.005). Overall image quality of navigated LAVA was also better than that of BH-LAVA in patients with sufficient breath-holding capacity (n = 309, 3.96 ± 0.88, 3.81 ± 0.66, respectively, P < 0.001). CONCLUSION: The navigated LAVA sequence could provide better image quality and diagnostic performance in detecting FLLs than BH-LAVA in patients with limited breath-holding capacity during HBP of gadoxetic acid MRI.[Abstract] [Full Text] [Related] [New Search]