These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: True aneurysm in a prosthetic aorto-femoral dacron graft.
    Author: Friedman M, Zelikovski A, Mor C, Reiss R.
    Journal: J Cardiovasc Surg (Torino); 1989; 30(1):136-7. PubMed ID: 2522452.
    Abstract:
    Aneurysms occurring in prosthetic grafts are a very rare phenomenon. However, false aneurysms are a known complication which can appear in the anastomotic site of the graft, but very seldom in the middle of the prosthetic graft. True aneurysm of a dacron graft is extremely rare, and very few have been reported in the literature. We present a case report of true aneurysm of a dacron graft that was implanted seven years before, found on a routine examination and confirmed on a pathological examination and successfully operated upon.
    [Abstract] [Full Text] [Related] [New Search]