These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Is the upgrade rate of atypical ductal hyperplasia diagnosed by core needle biopsy of calcifications different for digital and film-screen mammography?
    Author: McLaughlin CT, Neal CH, Helvie MA.
    Journal: AJR Am J Roentgenol; 2014 Oct; 203(4):917-22. PubMed ID: 25247961.
    Abstract:
    OBJECTIVE: The purpose of this study was to establish the upgrade rate of atypical ductal hyperplasia (ADH) diagnosed by stereotactic vacuum-assisted core needle biopsy for calcifications detected by digital mammography as compared with film-screen mammography. MATERIALS AND METHODS: A retrospective record search identified 101 cases of ADH. Criteria included women with calcifications biopsied using stereotactic vacuum-assisted core needle biopsy at our institution between January 2001 and December 2011. The center transitioned from film-screen mammography in 2001 to all digital mammography by 2010. Stereotactic vacuum-assisted core needle biopsies were performed using 11-gauge (59/101 [58%]) or 8-gauge (42/101 [42%]) needles. All pathology was interpreted by breast pathologists using standard criteria. RESULTS: Of 101 cases of ADH, 57 (56.4%) were detected using digital and 44 (43.6%) were detected using film-screen mammography. Seven of 57 (12.3%) cases of ADH detected by digital mammography were upgraded to ductal carcinoma in situ (DCIS) (n = 6) or invasive cancer (n = 1). Six of 44 (13.6%) cases of ADH detected by film-screen mammography were upgraded to DCIS (n = 5) or invasive cancer (n = 1) (p = 0.84). There was a trend toward low-grade DCIS in cases detected by digital mammography (3/7 [42.9%]) as compared with film-screen mammography (1/6 [16.7%]) (p = 0.68). A nonsignificant overall higher percentage of upgrades occurred when calcifications were not completely removed (10/52 [19.2%]) as compared with completely removed (3/47 [6.4%]). There was no difference in upgrade rate of stereotactic vacuum-assisted core needle biopsy performed using 11-gauge (7/59 [11.9%]) versus 8-gauge (6/42 [14.3%]) needles. CONCLUSION: The upgrade rate of ADH diagnosed by stereotactic vacuum-assisted core needle biopsy was not significantly different between digital and film-screen mammography. The current recommendation for excision of ADH diagnosed by stereotactic vacuum-assisted core needle biopsy should be applied to ADH detected by digital mammography.
    [Abstract] [Full Text] [Related] [New Search]