These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Two-dimensional measurement of blood flow velocity in rat arteries based on ultrasonic particle image velocimetry]. Author: Zhu Y, Qian M, Niu L, Zheng H, Lu G. Journal: Nan Fang Yi Ke Da Xue Xue Bao; 2014 Aug; 34(9):1305-9. PubMed ID: 25263364. Abstract: OBJECTIVE: Ultrasonic pulse wave Doppler technique for noninvasive blood flow imaging does not provide precise information of complex blood flow field, and observing two-dimensional artery blood flow field distribution provides important clinical information for cardiovascular disease. METHODS: Ultrasonic particle image velocimetry (Echo PIV) was used to measure blood flows on B-mode ultrasonic particle image to assess the whole field velocity of the blood vessels in 5 groups of healthy rats. The reliability of Echo PIV was verified in comparison with ultrasonic Doppler method in 3 cardiac cycles. RESULTS AND CONCLUSION: The results of Echo PIV were similar with the those of ultrasound spectral Doppler. The Echo PIV-measured peak and average velocity within 3 cardiac cycles were about 5%-10% and 2%-8% below the values measured by the ultrasonic spectral Doppler, respectively, but these differences were not statistically significant (P>0.05). As a new technique for monitoring complex blood flow in stenotic arteries, echo PIV can be used to directly and non-invasively assess whole field hemodynamic changes in blood vessels in real time and distinguish different groups of rats by velocity.[Abstract] [Full Text] [Related] [New Search]