  • Title: Conversion of adult Nucleus® 5 cochlear implant users to the Nucleus® 6 system.
    Author: De Ceulaer G, Swinnen F, Pascoal D, Philips B, Killian M, James C, Govaerts PJ, Dhooge I.
    Journal: Cochlear Implants Int; 2015 Jul; 16(4):222-32. PubMed ID: 25284643.
    Abstract:
    OBJECTIVES: Cochlear's new sound processor system (Nucleus(®) 6) features a new noise reduction algorithm called SNR-NR (signal-to-noise ratio), and an environmental classifier called SCAN, which activates the appropriate sound coding algorithms for a given listening environment. In addition, the sound processors (CP910 and CP920) have a data logging feature with data visually summarized using clinical programing software and come with two remote controls, CR210 and CR230. The objective of this clinical study was to conduct a field acceptance study comparing the user experience with the Nucleus(®) 6 to the Nucleus(®) 5 system and to evaluate the benefits of Nucleus(®) 6 in an adult population currently equipped with the previous generation Nucleus(®) 5 sound processor. Our primary objective was to compare speech recognition in speech-weighted noise using Nucleus(®) 6 with SCAN (activating SNR-NR) with the default Nucleus(®) 5 'Noise' Program. Secondary objectives included comparisons of speech recognition in quiet, subjective performance feedback via questionnaires and diaries, and recipient preference for device and program type. METHODS: A prospective controlled trial was conducted with 30 adult Nucleus CI recipients using the Nucleus(®) 5 sound processor (condition A). The Nucleus(®) 6 sound processor (condition B) was evaluated in a within-subject ABBA design, with repeated speech in noise (S0N0, LIST sentence test), and speech in quiet testing (S0, NVA words). The remote controls were randomly given during the two B intervals. In addition, recipients had to complete questionnaires and diaries on the use of their current as well as new sound processors and remotes. RESULTS: The group mean speech reception threshold in noise (SRT50) with Nucleus(®) 6 SCAN was significantly better (1.2 dB SNR) than with the Nucleus(®) 5 'Noise' Program. Mean speech recognition scores in quiet were not significantly different between the processors. Subjective performance feedback (APHAB) did not show a significant difference between Nucleus(®) 6 and Nucleus(®) 5 with high satisfaction scores being reported for both sound processors. Recipients preferred the SCAN program in noise and reported a clear overall preference for the Nucleus(®) 6 system. Clinicians were satisfied with the conversion process from Nucleus(®) 5 to Nucleus(®) 6. DISCUSSION AND CONCLUSION: SNR-NR provides a significant benefit in noise. Recipients were easily converted from Nucleus(®) 5 to Nucleus(®) 6 requiring little or no sound quality adjustment period. The Nucleus(®) 6 SCAN program was well accepted by the majority of recipients for use during their daily life.
    [Abstract] [Full Text] [Related] [New Search]