These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Determination of serum nadolol levels by GLC--selected ion monitoring mass spectrometry: comparison with a spectrofluorometric method.
    Author: Funke PT, Malley MF, Ivashkiv E, Cohen AI.
    Journal: J Pharm Sci; 1978 May; 67(5):653-7. PubMed ID: 25332.
    Abstract:
    A method to determine the serum concentration of the beta-adrenergic receptor blocking agent, nadolol, by GLC--selected ion monitoring mass spectrometry of the tri(trimethysilyl) ether derivative is described. A basic solution of serum was extracted, known amounts of internal standard were added to the extract, and the extract was back-extracted into acidic media and lyophilized. The resulting solids were reacted with N-trimethylsilylimidazole. Coded serum samples of 12 subjects, given nadolol alone or in combination with a second drug, were analyzed. The ions at m/e 86 and 100 were monitored to establish the relative concentration ratio of nadolol and the internal reference N-methylnadolol. No interferences from blood components or other administered drugs were observed. A detection level of 6.95 ng/ml of serum was found.
    [Abstract] [Full Text] [Related] [New Search]