These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Transplant renography: 99m-Tc-DTPA versus 99m-Tc-MAG3. A preliminary note.
    Author: Fraile M, Castell J, Buxeda M, Cuartero A, Cantarell C, Domenech-Torné FM.
    Journal: Eur J Nucl Med; 1989; 15(12):776-9. PubMed ID: 2533892.
    Abstract:
    99mTc-MAG3 has been proposed as a replacement for both 131I-hippuran and 99mTc-DTPA on clinical grounds. We undertook a prospective preliminary study to ascertain whether 99mTc-MAG3 works better than 99mTc-DTPA in the follow up of renal transplant recipients. Seventeen patients (21 renograms each MAG3 and DTPA) were studied, together, with a reference group of 10 patients in whom MAG3 and Hippuran clearance rates were determined simultaneously. As expected, 99mTc-MAG3 analog images were excellent and 99mTcMAG3 clearance correlated very well with 131I-hippuran clearance (r = 0.978). MAG3 values were 60% of hippuran values. However, when the corresponding renographic and perfusion findings were faced with different diagnostic challenges, such as post transplant renal failure and rejection, 99mTc MAG3 did not differ from 99mTc-DTPA in a significant way. 99mTc-DTPA was superior to 99mtc-MAG3 in one case of rejection.