These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Significance of leukocyte scintigraphy of the infected total endoprosthesis].
    Author: Becker W, Pasurka B, Börner W.
    Journal: Rofo; 1989 Mar; 150(3):284-9. PubMed ID: 2538877.
    Abstract:
    31 patients with suspected septic loosening of an endoprosthesis (hip endoprosthesis n = 30; knee endoprosthesis n = 1) were examined with leukocyte scans (10 MBq 111In-oxine: n = 22; 300 MBq 99mTc-HMPAO: n = 9). The results were compared with results of the bacterial growth (n = 22), the histology (n = 12) and of the bone scans (99mTc-MDP: n = 20) which were performed within 4 days. The sensitivity of the bone scan was 100%, the specificity 30% and the diagnostic accuracy regarding a septic loosening of the arthroplasty was 55%. For the leukocyte scans a comparable sensitivity of 100%, but a higher specificity (86%) and accuracy (91%) could be calculated. A false positive leukocyte scan could be observed in a periprosthetic granuloma, an ossifying periarthritis and in a patient with negative bacterial growth with the histological proof of an inflammation.
    [Abstract] [Full Text] [Related] [New Search]